Project's information:

Membrane covering:

Used membrane covering, we made as a double layer with air cushion between layers. Double PVC layer is a very good thermal insulator in winter (air void insulates hall against frost penetration) and summer conditions (insulation against sunlight rays limits hall’s heating). Thanks to the air cushion, hall’s layers are well-tensioned and they do not flutter in the wind.

 

Layers blowing system:

The system of layers blowing that maintains the air pressure between layers that create the air cushion.

 

Lights made of milky membrane transmit light very well. They are installed in the roof and they are led in two strips. They perfectly light the hall. The light is dispersed, it does not dazzle and it evenly illuminate the hall; used lights are available within two strips at the width of2.50 mper hall’s length; auxiliary lighting allows playing without dummy auxiliary light during the day time.

 

Illumination

Meta-halogen lamps are asymmetrically arranged, power: 400 W per each, Philips brand projectors

 

Heating:

Furnace at appropriately selected heating power, air heater burned with furnace oil or natural gas together with necessary instrumentation

 

Systems of open sides:

screen system: installed in the awning over open sides with top guide; material is led on the rollers and thanks to this it can be moved from one side to the another;

roller shade system: electronic sides raising, the system opens and closes one side within 1 minute; this system is maintenance-free. Awnings over open sides drain the rainwater and snow to the outside of the hall.

 

Details:

Hall dimensions:

– width from 20.00,0 to75.0 m

– length from 40.0 to105.0 m

– height 8,0-15.0m

 

Construction design:

4 copies

 

Foundation:

spot footings

 

Structure:

Curved steel or wooden structure

 

Realization time: 3 – 5 months